Burning Behaviour Test

It determines if, and to what degree, a fire will propagate in a dust-layer once started by an outside source. The result is either given by a “combustion number” or the rate of propagation of the fire.
The test equipment comprises an electrically heated glowing platinum wire at approx. 1000 °C (diameter: 1 mm, length 86 mm, current 30 A).

burning

 

Specifications

  • 1 x platinum hot coil current control unit
  • 1 x heater power handset (pre-wired into the control unit)
  • 1 x insulating block,1 x glass tube,1 x 100 mm length of platinum wire
  • 100 - 200 V / 220 - 240 V - 6 A input
  • Fine coil output current control (optimum 29 to 31 A. Control derived from low voltage d.c output)

What data we get?

Observations

Class at RT

No Spreading of fire

No Ignition

1

Brief ignition and rapid extinction

2

Localized combustion

3

Fire Spreads

Glowing without sparks

4

Slow quite burning with flames

4

Flash fire and violent spreading

6

 